PCB Testing in China
Bare-board electrical test, AOI, X-ray, impedance and solderability each detect a different defect class. A test claim is only meaningful with a coverage figure.
PCB Testing: recorded factories
Ordered by evidence strength, then by most recent review. Each profile states what was checked, on what date, and which processes are subcontracted rather than performed on site. A listing is not a guarantee of factory ownership or certification validity.
Lanshun Technology (Shenzhen)
Lanshun lists 19 SMT machines and no board-making gear, yet its own table quotes 46 layers. Registered scope stops at assembly. Who makes the bare board?
SEIC (Shenzhen Shinelong Electronics)
SEIC pages say 75, 400 or 500 staff and put the plant at 1,800 or 12,000 square metres. A buyer's question list built from the differences.
Cixi Qingbao Electronic Technology
Cixi Qingbao publishes 3 mil line/space; a 2026 Ningbo government article says 0.15 mm. Both are in print, neither is dated, and output figures differ too.
Compeq Huizhou (Boluo)
Compeq's 1995 Boluo plant holds 170,000 m2 and 3,200 staff, but the data-centre products sit with the Thai plant, not with Huizhou.
Dongguan Dingxin Circuit
Dingxin's milestone page ends at a 2018 Hunan plant, but filings show that plant was exited in 2023 and capital was cut in 2025.
Dongguan Viafull Circuit Technology
Viafull publishes UL file E466925, a checkable number, yet its own page quotes both 1-14 and 2-16 layers and 180 staff against 41 in filings.
Dongguan Yuejie Circuit Technology
Yuejie lists 64 layers, 10oz copper and IC substrates, yet its registry record shows three staff, four former names and a residential address.
Huizhou Glorysky Electronics
Glorysky's process table runs three year columns: 32 layers now, 36 in 2027 and 78 in 2028. Directories quote the last column as if it were today.
JCD (Jingchengda)
Jingchengda's Chinese profile claims 2,000 staff and two plants; its English page says 860 staff and one plant, fewer people than Taishan employs.
JOVEPCB (Zhongfu Circuit)
JOVEPCB describes three production bases in Chinese and five in English, and quotes 34 layers that turn out to be a prototype limit, not a production one.
King Brother (KINGBROTHER)
Kingbrother books 100,000 PCB part numbers a year, while an older page on the same site implies 120,000. Neither figure is in square metres.
Mektec Manufacturing (Zhuhai)
Zhuhai's flex plant is filed as wholly owned but registered 80/20, runs 1.25 million m2 of FPC a year, and publishes no process table.
Ningbo Dongya Circuit Board (Beilun)
Dongya's dypcb.com lands on a domain-parking page and nbdypcb.com returns 502, so every Beilun capacity figure comes from a parent site or a directory card.
Ningbo Kehaoda Electronics
Kehaoda's one spec page quotes a 26:1 aspect ratio and 12 mil laser drills on a 4,500 m² site, while its 2024 environmental filing covers a single-sided line.
Ningbo Wakan Electronic Science & Technology
Wakan's domain is dead and its only first-party pages are two WeChat posts. The Kelvin test claims are auditable; the headcount and capacity are not.
Ningbo Zonbo Electrical
Zonbo claims 12,000 m² of PCB fabrication a month, yet its registered scope covers appliances and auto parts and every catalogue item is an assembled board.
Putian Technology PCB (formerly GCI Jiesai)
Putian Technology is a CETC-controlled listed group whose PCB arm runs two named bases. Its 88-layer claim sits beside a 40-layer design limit.
Q&D Circuits (Qiangda)
Q&D Circuits runs 50-layer builds and 10,000 part numbers a month from Shenzhen, but its own pages disagree on whether it employs 1,200 people or 1,350.
Shanghai Jiajietong (Fast-PCB)
Jiajietong's Jiading address runs real etch lines - two plants plus a 2025 expansion - yet the same site prints four plant-area pairs and three age claims.
Shanghai Meadville Electronics (SME, AKM Meadville)
TTM sold Shanghai Meadville and substrate sister SMST to AKM Meadville for US$550m in 2020 - yet recruitment pages still describe SME as a TTM member.
Shenzhen Lianshuo Precision Electronics
Lianshuo's site claims a 2002 founding and 2003 certifications, but its registry date is 2012 and its own certificate page lists only ISO9001.
Universal Scientific Industrial (Shanghai) (USI)
Zhangjiang assembles for a group that shipped 1.08 billion units in 2024, but USI fabricates no bare boards - it buys them. Ask fabrication elsewhere.
Xunjiexing (JXPCB)
Xunjiexing's site gives 2.8 million m2 a year, 2.6 million in an article, and 1.84 million when the four plants are added up one by one.
What this service covers
Testing is not one service. Each method detects a specific defect class and is blind to the others:
- Bare-board electrical test checks continuity and isolation against the netlist. Flying probe needs no fixture and suits prototypes; a dedicated fixture is faster per board and only makes sense at volume.
- AOI compares the board or assembly against a reference image. It finds missing, misaligned and wrongly oriented parts, and solder defects that are visible from above.
- X-ray sees hidden joints: BGA, QFN thermal pads, and through-hole fill on thick boards. It is the only non-destructive method for area-array solder.
- Impedance test measures a coupon on the panel, not the board itself. It validates the stack-up and the trace geometry together.
- Solderability and surface-finish checks answer whether the board can be assembled at all, which is a different question from whether it is connected correctly.
A supplier that says “tested” without naming the method and the coverage has said nothing you can compare.
What decides whether the test is meaningful
- Coverage, stated as a percentage of nets or of nodes. A flying-probe program that covers 70 % of nets will pass a board with a fault in the other 30 %.
- Test point access. Nets with no probe access cannot be tested. This is a layout property, and it is fixed before the board is fabricated.
- Fixture cost and ownership. A dedicated fixture is a one-off cost that belongs to someone. If the factory owns it and you change supplier, the fixture does not travel with the design unless the contract says so.
- Pass and fail criteria. What counts as a fail, and what happens to a board that fails. Rework, scrap and retest should be defined, not negotiated per lot.
- Coupon versus board. Impedance and solderability are usually measured on a coupon that travels with the panel. That is normal, and it should be stated rather than implied.
What drives the price
- Number of test points and nets, which sets probe time.
- Fixture NRE at volume, and probe programming at prototype quantity.
- Test method, with flying probe slow per board and a fixture fast but expensive to build.
- X-ray inspection time, which is priced per image or per unit for area-array work.
- Retest and rework allowance, which some factories include and others bill after the fact.
What we check before listing a factory here
- The factory states which test methods are in-house and names the subcontracted ones.
- Coverage is reported as a number for each method, not as a general claim of full test.
- Test point access is checked during DFM review, before fabrication, rather than discovered at test.
- Impedance coupons are part of the panel design for controlled-impedance boards, and the measured values are recorded.
- Fail handling is defined: what is reworked, what is scrapped, and who is notified.
- Test records are retained and can be retrieved against a lot number.
Where it goes wrong
- “100 % electrical test” with 60 % net coverage. The claim is technically true and commercially misleading.
- No test points on a dense board. The nets that most need testing are the ones with no access.
- AOI used as a substitute for X-ray. Area-array joints are invisible from above, and the board passes.
- Fixture owned by the supplier. Changing supplier means paying for a new fixture and losing the test history.
- Coupon measured, board assumed. The coupon passes and the panel is not representative, usually because of a plating variation across the panel.
How it differs from neighbouring services
Assembly services place components; testing verifies the result. Fabrication services build the bare board, where electrical test is the last step before shipment. The same word covers both, which is why the coverage figure matters more than the label.
What to send in an RFQ
The netlist and test-point list, the assembly drawing for AOI and X-ray, the impedance targets for controlled-impedance boards, the required coverage, and the acceptance criteria. The testing quote specification lists the fields that change the price.
If the design has no test points yet, read PCB design services before fabrication; test access cannot be added after the board exists.