Dongguan Viafull Circuit Technology
东莞市玮孚电路科技有限公司 · Dongguan, Guangdong · Founded 2010 · Not listed; RMB 5m capital
Viafull publishes UL file E466925, a checkable number, yet its own page quotes both 1-14 and 2-16 layers and 180 staff against 41 in filings.
Viafull is a small Dongguan multilayer and metal-based board maker with one checkable item: UL file E466925. The rest of its page is less stable, with 1-14 layers beside 2-16 layers, ISO9001:2008 and 180 staff against 41 in filings. Verify the UL file first, then treat the rest as claims.
Identity and record
| Registered name (Chinese) | 东莞市玮孚电路科技有限公司 |
|---|---|
| Registered name (English) | Dongguan Viafull Circuit Technology Co., Ltd. |
| Founded | 2010 |
| Listed | Not listed; RMB 5m capital |
| Headquarters | Dongguan, Guangdong |
| Production sites | Shatian, Dongguan |
| Unified social credit code | 914419005608053335 |
| UL file number | E466925 |
| Official website | http://www.viafull.com/ |
| Evidence level | Public sources reviewed |
| Last reviewed | 2026-11-11 |
One number you can actually look up
Most profiles on this site run into the same wall: a list of certification names with nothing behind them. Viafull is different in one specific way. Its about page prints a UL file number, E466925, alongside ISO9001:2008, a REACH (138) report and a RoHS report. A UL file number is a lookup key. A buyer can go to the UL product database, enter the number and see the applicant name, the address on the file and the category of product covered.
That single field changes how the rest of the page should be read. Start the audit with E466925: if the UL record names Dongguan Viafull Circuit Technology at an address in Shatian, then at least one production approval belongs to this entity and the page has a verifiable anchor. If it names another company, or the number does not resolve, the whole certification paragraph needs to be re-questioned. I did not query the UL database for this profile, so the number is reported here as a published claim with a verification path, not as a confirmed registration. It is the first item to put on an RFQ.
Two layer ranges in one page of prose
The about page says the company offers custom products from 1 to 14 layers across different thicknesses, materials and processes. A few lines further down, the same page says it mainly produces multilayer boards from 2 to 16 layers, high Tg heavy copper foil boards, electrolytic and immersion gold boards and HASL boards. Both statements sit in the same document with no note explaining the difference.
The likely reading is that one figure describes the custom range and the other a production speciality, but a buyer cannot tell which one governs a 16-layer order. Layer count is the first field in most PCB capability comparisons, and a two-layer spread at the top end is the difference between a routine quote and a no-bid. Ask for a dated capability table with a single maximum layer count, the board thickness range behind it, and the surface finishes available at that layer count. The website is not a substitute for that table.
180 people on the site, 41 in the filings
The official page says the company has more than 180 experienced staff and more than ten years of board-making experience. A commercial registry report on the same company records 41 employees in 2025, registered capital of RMB 5 million, incorporation on 11 August 2010 and an address at Room 505, Building 4, 13 Huanbao South Road, Shatian. It classifies the business under printed circuit board manufacturing and notes a 2026 provincial innovative SME designation.
Headcounts diverge for ordinary reasons: annual returns count insured employees, while a website may count production workers supplied through a labour arrangement or a second site. But a 60,000 square metre monthly capacity with 41 insured staff is a large gap, and a room number as a registered address does not describe a plant. Ask which site the 60,000 square metres belongs to and whether there is a separate production entity. That question also determines where a factory audit should actually take place.
A certification paragraph that has aged
The opening paragraph claims ISO9001 (printed as IS09001 with a zero), IATF 16949, UL, SGS and CQC. The lower section lists ISO9001:2008, UL E466925, a REACH (138) report and a RoHS report. ISO 9001:2008 was superseded by the 2015 edition, and the “REACH 138” wording refers to a substance count in a test report rather than a management system. SGS and CQC are testing and certification bodies, not approvals in themselves.
None of this proves the approvals have lapsed. It shows the public page has not been maintained, which is common for a small factory and worth reading as a signal about how current the rest of the numbers are. If an automotive programme needs IATF 16949, request the certificate PDF with its scope annex and check that the address matches the plant you intend to use. Do not accept the acronym list.
What the product description is good for
Where the page is useful is in defining the shop’s shape: double sided and multilayer rigid boards, high Tg heavy copper, aluminium and metal-based work, ENIG and HASL finishes, and a stated test regime covering open and short circuit, impedance, solderability, thermal shock, microsection analysis and halogen-free testing. It names eight surface treatments and says samples carry no extra charge on a later production run.
That is a conventional small-to-medium multilayer and metal-based profile, not an HDI or substrate line. For an overseas buyer it screens well against commodity industrial, appliance and LED boards, and poorly against high-layer-count or fine-line work. Use it as a positioning statement, then confirm with the capability table. The gap between 1-14 and 2-16 layers is exactly where the first technical question should go.
Before this factory goes on a shortlist
- Look up UL file E466925 in the UL database and record the holder name, address and product category.
- Request a single dated capability table with one maximum layer count, thickness range, copper weight and finishes.
- Get current certificate PDFs with scope annexes. The page quotes ISO9001:2008 and mixes certification bodies with approvals.
- Ask which legal entity and which site deliver the 60,000 m2 monthly figure, and where its environmental approval sits.
- Reconcile the 180 staff claim with the 41 employees in the 2025 filing before planning a site audit.
Published limits
Every value below is quoted as published by the company or a public record.
| Parameter | Value as published |
|---|---|
| Official monthly capacity and founding | Founded 2010; monthly capacity above 60,000 m2 for double sided and multilayer boards |
| First layer range on the same page | Custom products from 1 to 14 layers across different thicknesses, materials and processes |
| Second layer range on the same page | Main production of multilayer boards from 2 to 16 layers, high Tg heavy copper, ENIG and HASL |
| Published UL file number | US UL certification with file number E466925; also lists ISO9001:2008, REACH (138) and RoHS reports |
| Systems named in the opening paragraph | IS09001, IATF16949, UL, SGS and CQC certifications claimed in the company introduction |
| Staff and test regime | 180-plus experienced staff; open/short, impedance, solderability, thermal shock and microsection tests |
| Registered entity basics | Founded 2010-08-11; USCC 914419005608053335; RMB 5m capital; 41 staff in 2025 |
| Registered address and classification | Room 505, Building 4, Shatian; classified as printed circuit board manufacturing; 2026 innovative SME |
Certifications on record
A certificate covers a legal entity and a site, not a brand. Scope and expiry are recorded where published.
| Standard | What the record shows |
|---|---|
| UL E466925 | A published UL file number, checkable in the UL database. No scope, issue date or holder name given on the page. |
| ISO9001:2008 | The 2008 edition was superseded by ISO 9001:2015; the page also prints IS09001 with a digit zero in one place. |
| IATF 16949, SGS, CQC | Named in the opening paragraph with no certificate numbers, scopes or issuing bodies; no separate certificate page found. |
| REACH (138) and RoHS | Reports are listed rather than certificates; the 138 substance count refers to a test report, not a quality approval. |
Ask this factory for a quote
Send one technical package and compare the replies. The RFQ checklist lists what to include; the quote specifications say which parameters change the price for the process you are buying.
Source and review conventions are described in how we verify. Corrections can be sent through the contact channel.