PCB Drilling in China
Mechanical and laser drilling of vias and component holes. Hole count sets the price; aspect ratio, stack height and registration accuracy decide whether the job can run at all.
PCB Drilling: recorded factories
Ordered by evidence strength, then by most recent review. Each profile states what was checked, on what date, and which processes are subcontracted rather than performed on site. A listing is not a guarantee of factory ownership or certification validity.
Cixi Qingbao Electronic Technology
Cixi Qingbao publishes 3 mil line/space; a 2026 Ningbo government article says 0.15 mm. Both are in print, neither is dated, and output figures differ too.
Huizhou Glorysky Electronics
Glorysky's process table runs three year columns: 32 layers now, 36 in 2027 and 78 in 2028. Directories quote the last column as if it were today.
Jiangsu Difeida Electronics
The Difeida name covers a 1997 PCB fab and a separate EMS company that carried NEEQ code 873105. Only one of them owns dfd338.com and the drill floor.
Ningbo Dongya Circuit Board (Beilun)
Dongya's dypcb.com lands on a domain-parking page and nbdypcb.com returns 502, so every Beilun capacity figure comes from a parent site or a directory card.
Ningbo Kehaoda Electronics
Kehaoda's one spec page quotes a 26:1 aspect ratio and 12 mil laser drills on a 4,500 m² site, while its 2024 environmental filing covers a single-sided line.
What this service covers
Drilling creates every hole in the board: component holes, mechanical vias, laser microvias and tooling holes. It is the step where layer registration is established, so an error here propagates through plating and cannot be corrected later.
Two processes dominate. Mechanical drilling uses a rotating bit through a stack of panels; it is fast per hit and limited by bit diameter and aspect ratio. Laser drilling removes dielectric with a focused beam, usually for microvias below 0,15 mm, and cannot drill through the full board thickness in one pass.
What decides whether the job can be drilled
- Aspect ratio, the finished hole depth divided by diameter. Mechanical drilling becomes unreliable as the ratio rises, because the bit wanders and the hole wall quality degrades. A factory’s stated maximum aspect ratio is a real constraint, not a marketing figure.
- Stack height. Panels are drilled in stacks to reduce cost per hit. A thicker stack is cheaper and less accurate, so the factory trades accuracy against price on every job.
- Hit accuracy and registration. The drill must land inside the pad on every layer. On high-layer-count boards, accumulated registration error is the main reason a design is rejected at this step.
- Entry and exit material. Entry foil and backing board protect the copper and control burr. Skipping them saves cost and produces burrs that show up as plating defects.
- Hole size tolerance and finished versus drilled diameter. Plating adds thickness to the wall. A drawing that states the drilled size and a drawing that states the finished size produce different parts.
What drives the price
- Total hole count per board, which is the primary unit, multiplied by panel quantity.
- Smallest hole diameter, since small bits drill slower and break more often.
- Aspect ratio, because high ratios force single-panel drilling instead of stacking.
- Laser-drilled microvias, which are priced per via and require a separate process.
- Backdrilling and countersink, which are additional operations on the same machine.
- Resin plugging or via filling, which follows drilling and is often quoted with it.
What we check before listing a factory here
- The factory states its maximum aspect ratio and the minimum mechanical drill diameter, per product series.
- Laser drilling is either in-house or explicitly subcontracted; the two are not interchangeable for microvia work.
- Hit accuracy is stated as a number, and the factory can show a registration check on a high-layer board.
- The factory distinguishes drilled diameter from finished diameter on its drill drawings, which is where most hole-size disputes start.
- Backdrilling capability is stated separately, because it needs depth control the standard process does not have.
- Scrap and rework rates for drilling are reported, since this step is where a board is most often lost.
Where it goes wrong
- Stack height pushed to cut cost. Registration drifts, the annular ring breaks out, and the defect appears after plating.
- Hole size quoted as finished. The finished hole is smaller than the drawing, and the connector no longer fits.
- Bit wear not managed. Hole wall quality degrades gradually, and the failure is only visible in cross-section.
- Microvia depth drilled into the wrong layer. The via looks correct from the surface and does not connect.
- Tooling holes drilled after pattern plating. The registration reference no longer exists, so every subsequent layer is offset.
How it differs from neighbouring services
Cutting defines the outline; drilling defines the holes and the layer-to-layer reference. Plating follows drilling and depends on its quality. A factory that quotes drilling without stating aspect ratio is quoting a hole count, not a capability.
What to send in an RFQ
The drill file with hole sizes and plating status, the stack-up, layer count, finished thickness, the smallest hole and the highest aspect ratio in the design, whether any vias are laser-drilled, and the quantity. The drilling quote specification lists the fields that change the price.
If the design has not been checked against a specific factory’s drilling limits, do that first; the capability comparison guide explains which numbers to compare.