Kehaoda's one spec page quotes a 26:1 aspect ratio and 12 mil laser drills on a 4,500 m² site, while its 2024 environmental filing covers a single-sided line.

Treat Kehaoda as a single and double-sided volume shop: 200 staff on 4,500 m², one line permitted at 800,000 m² a year. Its 26:1 aspect ratio and laser drills read like borrowed text from a larger fab. Make it quote a 6-layer stack before you accept the HDI and high-frequency tags.

Identity and record

Only entries that were checked against a source are shown. A blank field means we have not confirmed it, not that it does not exist.
Registered name (Chinese) 宁波科浩达电子有限公司
Registered name (English) Ningbo Kehaoda Electronics Co., Ltd.
Founded 1990
Listed Not listed
Headquarters Ningbo, Zhejiang
Production sites Yuyao (Binhai New City, Cao'e Road)
Unified social credit code 913302810975813815
Official website http://www.nbkehaoda.com/
Evidence levelPublic sources reviewed
Last reviewed2026-11-11
Registered entity and published production sites Registered entity Ningbo Kehaoda Electronics and 1 named production sites, from the disclosures cited on this page. PUBLISHED RECORD Ningbo Kehaoda Electronics 宁波科浩达电子有限公司 Founded 1990 · Not listed Yuyao Binhai New City,… Source: disclosures cited on this page
Entity and footprint map. Ningbo Kehaoda Electronics and the production sites named in the disclosures cited above.

A 4,500 m² site quoting a 26:1 aspect ratio

The company profile is modest: 4,500 m² of land, RMB 15 million of total investment, 200-plus staff, founded 1990. Those are the proportions of a single and double-sided shop in a Yuyao industrial park, the kind of plant that runs two shifts on FR-4 and ships to appliance and industrial-control accounts.

The product page is not modest. It quotes a 26:1 board-thickness-to-hole ratio, 12 mil laser drills, 3 mil lines at 30 µm finished copper, and a 600 by 800 mm maximum panel.

A 26:1 aspect ratio is not a number you get by wanting it. It needs high-throw plating, careful agitation, and a drilling room with depth control good enough to hold entry and exit burr across a thick stack. A plant doing that work usually has a plating line of a specific shape, and usually says so. Kehaoda says it in one line, on a page about something else.

The only page with numbers is an RFID handset board

Six of the seven navigation categories — industrial control, inverter power, HDI through-hole, amplifier, aluminium, high-frequency — have no data sheet at all. The single page that carries a process table is a product detail page for an RFID handheld board.

So the specifications you can read are attached to the least demanding product in the catalogue. That is backwards from how a real fab publishes: you put the generic capability table on a capability page and let products inherit it. Here the table exists once, by accident, inside a product listing.

800,000 m² a year is one line, not the plant

The 2024 environmental impact filing is the strongest document about this company, because a filing is a permission with an address and a name on it. It covers a single-sided printed circuit line at 800,000 m² a year, and it records the credit code 913302810975813815 and legal representative 钱银书.

Read that scope carefully. It is one line, permitted for single-sided product. It says nothing about the double-sided and multilayer work that the site’s categories imply, and it says nothing about monthly output. 800,000 m² a year is roughly 66,000 m² a month, which is a serious volume for a 4,500 m² building — and possible, because single-sided board is punched and processed fast.

What you cannot do is take that number and use it to size a 6-layer order. Different line, different permit, different economics.

Numbers that contradict each other on the same page

The specification block contains a “maximum copper thickness 0.5 oz” line sitting a few rows above a 30 µm finished copper figure. 0.5 oz base copper is about 17 µm; 30 µm finished copper with plating is roughly 1 oz. Those two statements describe different processes.

Laser-drilled 12 mil vias do not normally appear on a board that caps copper at 0.5 oz either — fine vias and thin copper travel together in HDI, and neither travels with a shop whose permitted line is single-sided.

The most economical explanation is that the block was pasted from another factory’s website, possibly a larger one, and never reconciled. That is common on Chinese brochure sites built around 2015, which this template appears to be. It does not mean Kehaoda cannot drill a 0.3 mm hole. It means the table cannot be used as a specification, and any tolerance you need has to be written into the purchase order by agreement.

Certificates named, honours page empty

ISO 9001, UL and SGS are all named in one sentence on the profile, with no numbers, no issuing body, no scope and no expiry. The 荣誉资质 page — the honours and qualifications page — renders empty.

SGS deserves a note. It is a testing and inspection company, not a management-system certification. Listing “SGS certification” next to ISO 9001 usually means somebody once paid for a RoHS test report. It is not a quality-system credential and should not be counted as one.

A six-layer test you can run in one email

Fit first. Kehaoda suits single and double-sided FR-4 at volume — appliance, power supply, LED, straightforward industrial control — where the 600 by 800 mm panel and the 0.3 mm drill are the real limits. It does not suit impedance-controlled multilayer or HDI until a stack-up comes back with numbers on it.

Send a 6-layer, 1.6 mm, 1 oz stack with 0.3 mm vias and ask four things: the layer count they will build in-house, the impedance tolerances they can hold, whether the panel comes from the 600 by 800 mm press or is stepped, and which line the order runs on.

If the answer comes back as a price without a stack-up, the multilayer categories are a shop window. If it comes back with a stack-up and a drilled panel size, the plant is more capable than its own website suggests — which happens, and is the reason to ask rather than to walk away.

What is not established

The 1990 founding year is a website claim only. No registry record could be opened from outside China to confirm it, and the site template itself dates to about 2015. Headcount, monthly capacity, layer ceiling, plant-wide copper range and the ISO certificate number are all unpublished. The UL file number is absent. Whether the double-sided and multilayer categories are built in Yuyao or brokered out is not stated anywhere.

One more caution: the site footer carries outbound links to unrelated domains. Treat the whole site as a low-maintenance brochure, and the filing as the only document that has been reviewed by anybody outside the company.

Published limits

Every value below is quoted as published by the company or a public record.

ParameterValue as published
Annual capacity of the single-sided line (2024 EIA filing) 800,000 m²/yr
Minimum line width and spacing, outer layer 3.0/3.0 mil at 30 µm finished copper
Minimum line width and spacing, inner layer 3/3 mil at 1/3 oz and 1/2 oz
Minimum drill diameter 0.3 mm mechanical, 12 mil laser
Board thickness to hole diameter ratio 26:1
Maximum finished panel size on the product page 600 x 800 mm
Minimum annular ring and solder mask bridge 6 mil annular ring, 0.08 mm mask bridge
Site area (company profile) 4,500 m²
Employees (company profile) 200-plus
Total investment (company profile) RMB 15 million
Two copper thicknesses, two processes Bar chart of 2 published figures in µm copper thickness as reconciled on this page. The block prints 0.5 oz base copper (about 17 µm) above 30 µm finished copper (roughly 1 oz). They describe different processes; the block appears pasted from another site. The 12 mil laser via is excluded. Base copper 17 µm 0.5 oz base copper, as printed Finished copper 30 µm 30 µm finished copper, about 1 oz
Two copper thicknesses, two processes. µm copper thickness as reconciled on this page. The block prints 0.5 oz base copper (about 17 µm) above 30 µm finished copper (roughly 1 oz). They describe different processes; the block appears pasted from another site. The 12 mil laser via is excluded. Source: RFID product page specification block.

Certifications on record

A certificate covers a legal entity and a site, not a brand. Scope and expiry are recorded where published.

StandardWhat the record shows
ISO 9001 Named on the profile with no certificate number, body or revision. No copy of the certificate is published.
UL Named only, as one of several certificates. No file number, product category or expiry, so it cannot be looked up in UL Product iQ.
SGS Listed as an SGS certification with no report number, standard or scope. SGS is a testing body, not a quality-system mark.

Ask this factory for a quote

Send one technical package and compare the replies. The RFQ checklist lists what to include; the quote specifications say which parameters change the price for the process you are buying.

Request a quote

Source and review conventions are described in how we verify. Corrections can be sent through the contact channel.