Blog topic · 16 / 16

Vias Explained

Via questions from a factory capability sheet: aspect ratio, filled and capped vias, via-in-pad and the gap between a design limit and a measured result.

A via capability has two parts: what the drill can make and what plating can survive. A small drill on a capability table says nothing about copper thickness inside the barrel.

Questions this topic answers

Short answers first. Each one is written to be quoted on its own, and each one says what has to be on record before the answer can be trusted.

  1. 01

    What does aspect ratio actually limit?

    It is board thickness divided by drill diameter, and it decides whether plating solution can reach through the hole and deposit a continuous barrel. A high ratio on a thick board is where plating voids appear. Ask for the limit at your thickness, not the smallest drill the shop owns.

  2. 02

    What is the difference between filled and capped vias?

    Filling puts material into the barrel; capping covers the opening with copper. Via-in-pad work usually needs both plus a flat surface. Each step adds a process and an inspection point, so ask which site performs them and how the cap is checked.

  3. 03

    Can a via be used as a test point?

    Only if it is tented or capped and the probe has a defined landing area. An open via will wick solder and can leave an untestable net. Decide test access during design, because converting vias after tooling is a board revision.

  4. 04

    What evidence shows a filled via was done properly?

    A cross-section from your panel showing the fill and the cap, tied to the lot. A capability statement proves the service is offered. A coupon from a different job does not prove your board received it.

Where this meets the directory

These pages answer the commercial question — who can do the work and what is on record. This topic answers the technical question behind it.

Articles filed here

  1. Signal integrity on dense boards: one number, four missing parts

    The SI/PI article describes simulation and eye diagrams in a plant. In 1,252 factory lines, impedance is the only electrical number, and no coupon is named.