PCB Drilling Quotes: Hole Count and Aspect Ratio
Drilling is quoted per hole and per stack. Mechanical drilling covers the mainstream range; below roughly 0.15 mm the work moves to laser, which is usually a different supplier. Aspect ratio matters more than diameter: a 0.3 mm hole in a 3.2 mm board is over 10:1 and needs controlled parameters and different entry material.
Lead times are industry ranges, not commitments. Any factory's actual date depends on its queue that week, and on what else is already scheduled.
ChinaPCB.org does not quote boards and takes no commission. This page exists so that the enquiry you send to a factory is complete the first time. Send it yourself — see how to send an RFQ.
What this quote is priced on
Five to seven variables move the number on a drilling quote. They are not equally important, and only the first two are usually discussed.
- Hole count per board. The primary multiplier, times panel quantity. A board with 800 holes is not twice a board with 400; it is priced nearly linearly on hits.
- Smallest diameter. Small bits drill slower and break more often. Below a certain size the process changes from drilling to laser, which is a different quote.
- Aspect ratio. Deep holes in a thick board force single-panel drilling instead of stacking, which multiplies machine time per board.
- Stack height. Drilling several panels at once reduces cost per hit and reduces accuracy. The trade is made on every job whether or not it is discussed.
- Additional operations. Slots, countersinks, backdrilling and resin plugging are separate operations on the same machine and are usually quoted separately.
- Plating status. Drilling after plating is a repair operation, not a fabrication step, and carries the risk of damaging the barrel.
The parameters a factory needs
This is the set that has to be in the enquiry before a drilling price means anything. The third column is why each one changes the answer, which is also the reason a quote that skips it is not really a quote.
| Parameter | What to state | Why it changes the answer |
|---|---|---|
| Drill file with hole chart | The drill file in a standard format, plus a chart of sizes and counts | The chart is the price basis. Without it the factory counts hits from the file and the two counts rarely agree. |
| Plated or non-plated holes | Which holes are plated through, which are mechanical, and any NPTH in pads | Plated and non-plated holes are separate operations. Confusing them ruins the barrel or the fit. |
| Board thickness | Finished thickness, and the thickness at the time of drilling | Aspect ratio is thickness divided by diameter. Without the thickness the aspect ratio, and therefore the price, is undefined. |
| Smallest hole and max aspect ratio | The smallest finished hole and the highest ratio in the design | This pair decides whether the job runs on a mechanical driller or moves to laser, which is a step change in cost. |
| Stack height allowed | The maximum panels per stack you will accept | Stacking lowers cost and accuracy together. Your tolerance on hole position decides how much stacking is permissible. |
| Slots and countersinks | Slot dimensions, countersink angle and depth, and their tolerance | These are separate tool paths and separate operations, frequently omitted from a drill enquiry and added later. |
| Laser-drilled vias | Which vias are microvias, their diameter and the dielectric to be drilled | Laser drilling is a different process with different minimums, and not every drill house has it in-house. |
| Whether the boards are already laminated | Bare laminate, laminated without plating, or fully plated and finished | Drilling after plating risks barrel damage and contamination. The answer changes the process and the risk allocation. |
Send with the enquiry
- The drill file plus a hole chart listing every size and its count.
- Board thickness and the smallest hole, so the aspect ratio can be checked.
- Which holes are plated and which are mechanical.
- Slot and countersink dimensions with tolerances.
- Whether the boards are bare laminate or already plated and finished.
Where it goes wrong
- Drilling finished boards without saying so. The process can damage plated barrels and leave debris in the holes. The boards fail electrical test and nobody knows why.
- Aspect ratio discovered at the machine. The job is quoted, scheduled and then rejected or run at a loss. Both outcomes cost you time.
- Hole size quoted as drilled when the drawing means finished. Plating narrows the hole. The connector no longer fits and the board is scrap.
- Stack height pushed to reduce price. Registration drifts and the annular ring breaks out. The defect appears after plating, when the board is worth much more.
Comparing two drilling quotes
Two prices are only comparable when the parameters above are held constant. Most of the spread buyers see comes from a difference in one of these, not from a difference in factory efficiency.
- Compare the hole count each supplier used. A difference there explains most of the price gap.
- Compare the aspect ratio accepted. One supplier may have quietly relaxed it to keep the price.
- Compare whether laser vias are in-house or subcontracted. Subcontracting adds a day and a handling risk.
- Compare what is included: plugging, countersink and backdrill are often quoted separately by one supplier and included by another.
What this page does not tell you
This page gives no maximum aspect ratio figure, because it is factory-specific and depends on the bit, the entry material and the tolerance you need. A number quoted without those three is a claim, not a capability.
Related
- PCB drilling: aspect ratio, stack height and hit accuracy
- Cutting quotes: the outline, not the holes
- 6-layer quotes: where registration starts to matter
- Testing quotes: proving the holes connect
Fee structure and editorial independence are described on the about page. What we can and cannot confirm about a factory is on how we verify.