PCB quotes

Rigid-Flex PCB Quotes: What to Send First

Rigid-flex is the format that gets misquoted most often, because the flex core has to survive being laminated into a rigid stack. The price sits in the mixed-material press cycle and in the tooling for coverlay and stiffeners, not in the layer count.

Lead times are industry ranges, not commitments. Any factory's actual date depends on its queue that week, and on what else is already scheduled.

Main cost driver
Lamination cycles, coverlay and stiffener tooling
Typical lead time
1–2 weeks for prototypes, 3–5 weeks for production

ChinaPCB.org does not quote boards and takes no commission. This page exists so that the enquiry you send to a factory is complete the first time. Send it yourself — see how to send an RFQ.

What this quote is priced on

Five to seven variables move the number on a rigid-flex quote. They are not equally important, and only the first two are usually discussed.

  • Number of lamination cycles. Each rigid section is pressed separately around the flex core. A three-section rigid-flex board can need three cycles, and each cycle carries its own registration risk and yield loss.
  • Coverlay versus solder mask on flex. Coverlay is cut and laminated with an adhesive, so it needs tooling and a placement step. Photoimageable coverlay removes the tooling but limits thickness and bend performance.
  • Stiffener material and bonding. FR-4, polyimide or stainless stiffeners are added after lamination. Each one is a separate operation, and bonding them flat is where bow appears.
  • Adhesiveless versus adhesive flex core. Adhesiveless polyimide is thinner, bends better and costs more. Adhesive cores are cheaper and limit dynamic bending, so the choice is a design decision disguised as a price decision.
  • Transition geometry. A wide transition with gradual taper costs nothing extra to design and a great deal to build badly. Narrow transitions concentrate stress and fail in test.
  • Test and handling. Flex sections cannot be probed like rigid boards without support. Fixtures and carrier panels add cost that a rigid quote never shows.

The parameters a factory needs

This is the set that has to be in the enquiry before a rigid-flex price means anything. The third column is why each one changes the answer, which is also the reason a quote that skips it is not really a quote.

Rigid-Flex RFQ parameter set. State every row, or accept the factory's default.
Parameter What to state Why it changes the answer
Which layers are flexible Layer numbers, and whether the flex core is a single core or several The stack is built around the flex core, so this decides the press sequence and therefore most of the cost.
Transition location and length A drawing with the rigid-to-flex boundary and the taper The boundary is where delamination and copper cracking happen. Its geometry sets the tooling and the yield.
Bend radius and flex cycles Minimum radius, static or dynamic, and the number of cycles if dynamic Dynamic bending restricts copper type, coverlay and layer count. A static-only part can use constructions that fail immediately in motion.
Coverlay or mask on flex Coverlay, photoimageable coverlay or solder mask, with thickness Decides whether tooling is needed and whether the part can bend at the radius asked for.
Stiffener specification Material, thickness and location, especially under connectors Stiffeners change the finished thickness and add bonding steps. Missing them from the enquiry produces a part that cannot be assembled.
Assembly carrier requirement Whether the flex section needs a carrier for SMT, and who supplies it Unsupported flex cannot pass a standard printer or reflow line. The carrier is often quoted separately and discovered late.
Copper type on flex layers Rolled annealed or electrodeposited copper Rolled copper survives bending and costs more. Electrodeposited copper is fine for static bends and cracks early in dynamic ones.
Acceptance criteria for bend Whether the part is bend-tested, and to what radius and cycle count Bend test is a destructive sample test with its own cost. Without it, the first bend evaluation happens in your assembly.

Send with the enquiry

  1. A stack drawing that marks the flex core and every rigid section, with the transition dimensioned.
  2. The bend radius, the number of cycles if the part moves, and whether the bend is formed once at assembly.
  3. Coverlay or mask on the flex sections, and the stiffener material and thickness under each connector.
  4. Whether the flex tail will go through SMT, and if so whether a carrier is expected from the factory.
  5. The copper type on flex layers, or the bend requirement if you have no preference.

Where it goes wrong

  • Quoted from a rigid stack. A supplier who prices rigid-flex using rigid rules builds a board that delaminates at the transition after the first reflow.
  • Coverlay tooling counted late. Coverlay needs a cut file and a lamination fixture per design. Quotes that omit it come back with an addition after the design is frozen.
  • Stiffeners left to the factory. The stiffener thickness changes the connector height. Left unspecified, the part arrives at a thickness your housing does not accept.
  • Dynamic bend quoted as static. A static construction is cheaper and passes a single bend. It fails after a few thousand cycles, quietly, in the field.

Comparing two rigid-flex quotes

Two prices are only comparable when the parameters above are held constant. Most of the spread buyers see comes from a difference in one of these, not from a difference in factory efficiency.

  • Compare the number of lamination cycles each supplier assumes. A two-cycle and a four-cycle quote are not the same process.
  • Check whether coverlay tooling is included or listed separately. The headline number is often the one without tooling.
  • Ask both suppliers for the flex copper type. Rolled annealed and electrodeposited differ in both price and bend life.
  • Compare the test method for the transition: cross-section, bend test, or visual only. The cheap quote usually tests visually.

What this page does not tell you

This page does not tell you whether your particular transition will survive your bend radius. That depends on copper type, coverlay and layer count together, and the honest answer is a bend test on a sample, not a quote.

Related

Fee structure and editorial independence are described on the about page. What we can and cannot confirm about a factory is on how we verify.