HDI PCB Quotes: The Build-Up Is the Quote
HDI price is driven by how many times the board is laminated. A 1+N+1 build is one extra cycle; a 3+N+3 or an any-layer stack is five or more, and each cycle adds a laser drill program, a plating step and a fresh registration risk.
Lead times are industry ranges, not commitments. Any factory's actual date depends on its queue that week, and on what else is already scheduled.
ChinaPCB.org does not quote boards and takes no commission. This page exists so that the enquiry you send to a factory is complete the first time. Send it yourself — see how to send an RFQ.
What this quote is priced on
Five to seven variables move the number on a hdi quote. They are not equally important, and only the first two are usually discussed.
- Sequential lamination count. Every build-up layer pair is its own press cycle. The count, not the total layer number, is what the factory schedules and what fails.
- Laser via diameter and depth. Smaller diameter and deeper blind vias reduce the process window. Both are priced per via and both raise the scrap rate on the whole panel.
- Via fill and cap. Filled and capped vias are needed for via-in-pad. The fill process is a separate step and a common source of voids under the cap.
- Stacked versus staggered vias. Stacked vias concentrate stress on the same axis and demand better registration. Staggered vias are cheaper and take more routing area.
- Any-layer construction. Any-layer HDI removes the core and builds every layer as a build-up. It is the most expensive option and the only one that reaches the smallest pitch.
- Test and inspection. Microvias cannot be probed directly. AOI, cross-section and sometimes X-ray are priced into the quote whether or not they are listed.
The parameters a factory needs
This is the set that has to be in the enquiry before a hdi price means anything. The third column is why each one changes the answer, which is also the reason a quote that skips it is not really a quote.
| Parameter | What to state | Why it changes the answer |
|---|---|---|
| Build-up notation | For example 1+N+1 or 3+4+3, with the core thickness | The single most important field. Total layer count alone cannot be priced, and the same count can differ by a factor of three. |
| Laser via diameter and depth | Finished diameter, dielectric thickness to be drilled, and target pad | Sets the aspect ratio of the microvia and therefore whether it can be filled reliably. |
| Via fill and cap requirement | Filled and capped, filled only, or open, and whether vias sit in pads | Via-in-pad needs a fill-and-planarise step. Quoting without it produces pads that void under reflow. |
| Via stacking pattern | Stacked, staggered, or a mix, shown on a section drawing | Stacked vias drive registration requirements and cost. A drawing is the only reliable way to state it. |
| Core construction | Core-based or any-layer, and the core material and thickness | Any-layer removes the core entirely and changes the whole process flow, including the drill strategy. |
| Impedance targets | Single-ended and differential values, tolerance, and reference layers | Controlled impedance on a build-up stack requires the factory to own the stack-up. If you own it, say so. |
| Minimum line and space | The finest feature on the outer and inner layers separately | Outer layers on build-up film behave differently from inner layers on core. One number for both hides the constraint. |
| Annual volume and layer count mix | Volume per build-up variant, not the total across variants | Each variant is a separate tooling and program set. Averaging them makes the quote meaningless. |
Send with the enquiry
- The build-up in section, with notation and every dielectric thickness.
- Laser via diameter and the pad it lands on, plus whether vias are filled and capped.
- A section drawing showing stacked or staggered vias, and the minimum dielectric between them.
- Impedance targets with tolerance, and a statement of who owns the stack-up.
- Volume per build-up variant, and the layer count of each variant.
Where it goes wrong
- One price for "HDI". Layer count does not price HDI. A supplier who quotes without the build-up has priced an assumption, and the assumption is usually cheaper than your board.
- Via-in-pad without fill specified. Paste wicks into the via and the joint voids. The board passes AOI on the top side and fails thermal cycling later.
- Stacked vias drawn as staggered. The factory registers to the drawing, not the intent. Changing the pattern after tooling means new laser programs and a new price.
- Impedance added after the stack is fixed. Controlled impedance constrains dielectric thickness. Adding it late forces a stack rebuild, which restarts the lamination count.
Comparing two hdi quotes
Two prices are only comparable when the parameters above are held constant. Most of the spread buyers see comes from a difference in one of these, not from a difference in factory efficiency.
- Compare build-up counts first. If one quote is 1+N+1 and the other is 2+N+2, the prices are not comparable and never will be.
- Check whether laser via count per board is stated. It is the closest thing to a unit price in HDI.
- Compare who owns the stack-up and the impedance calculation. Two suppliers who both own it will produce two different boards.
- Ask what happens to a panel that fails registration at the third lamination. The answer tells you how the yield risk is priced.
What this page does not tell you
This page does not state a minimum laser via diameter, because the figure is factory-specific and changes with dielectric thickness. Treat any capability number you see without a stack attached as marketing.
Related
- HDI boards: build-up types and what each one costs you
- 6-layer quotes: the step before HDI
- Rigid-flex quotes: lamination cycles again
- Capability comparison: which numbers to line up
Fee structure and editorial independence are described on the about page. What we can and cannot confirm about a factory is on how we verify.